Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDurgut, Temel
dc.contributor.authorMaraş, Erdem Emin
dc.date.accessioned2023-09-04T08:28:56Z
dc.date.available2023-09-04T08:28:56Z
dc.date.issued30.06.2021en_US
dc.identifier.citationDurgut, T. & Maraş, E. E. (2021). Fotogrametrik Cerrahi Navigasyon Uygulamalarında Kamera ve Sistem Kalibrasyonunun Ölçüm Doğruluklarına Etkisi . Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi , 21 (3) , 640-649 . DOI: 10.35414/akufemubid.851780en_US
dc.identifier.issn2149-3367
dc.identifier.urihttps://dergipark.org.tr/tr/pub/akufemubid/issue/64196/851780
dc.identifier.urihttps://hdl.handle.net/11630/10547
dc.description.abstractKlasik cerrahi yöntemlerin taşıdığı riskleri ve cerrahi müdahale sürelerini en aza indirmek için günümüz teknolojik gelişmelerine paralel olarak fotogrametrik cerrahi uygulamalar gün geçtikçe daha da önem kazanmaktadır. Cerrahi müdahalenin yapılacağı bölgenin tamamen açılmasına ihtiyaç duyulmayan durumlarda belirlenen uygun bir noktadan giriş yapmak suretiyle kısa sürede ve daha güvenli cerrahi işlemler yapılabilmektedir. Cerrahi navigasyonda; standart bir ölçü biriminde tanımlı bir altlık üzerinde (MR, Tomografi, vb.), belirli periyotlarla takip edilen, 3 Boyutlu (3B) konumları belirlenen ve ulaşılmak istenen bir konuma yönlendirilen hareketli sondalar kullanılmaktadır. Söz konusu sondaların 3B hareketlerinin yüksek doğruluklarla ve gerçek zamanlı olarak konumlandırılabilmesi için kullanılan stereo kameraların fotogrametrik olarak kalibrasyona tabi tutulması büyük önem arz etmektedir. Bu çalışma kapsamında söz konusu kalibrasyonların sistemin konumlama doğruluğuna etkisi araştırılmıştır. Bu amaçla, kameralara ait iç yöneltme parametreleri ve sabit olan stereo kamera bazı ileri dengeleme teknikleri kullanılarak yeniden hesaplanmıştır. Çalışmada, sorumlu yazar tarafından 2014 yılından bu yana geliştirilmekte olan “Stereo Fotogrametrik Cerrahi Navigasyon Yazılımı” ve “Fotogrametrik Kamera Kalibrasyon Yazılımı” kullanılmıştır. Çalışma neticesinde; kalibrasyonu yapılmış sistem bileşenlerinin, gerçek zamanlı 3B konum doğruluğunu 2-3 mm seviyelerinden 0,2 mm seviyelerine çektiği görülmüş ve ayrıntılı olarak sunulmuştur.en_US
dc.description.abstractPhotogrammetric Surgical Navigation Systems are getting more importance day by day to minimize the surgical operation times and the risk of classical methods with respect to the technological developments. More reliable surgical operations are now possible in shorter times without opening the whole related location of the body if it is not necessary. In surgical navigation; moving surgical probes which are periodically tracked and navigated to a desired location on a layer that is defined in a standart measuring unit are used. It is of vital importance to calibrate the cameras photogrammetrically for real-time 3D movements of the probes to be located highly accurate. In this study; the effect of respective calibrations for measuring accuracy of the system is investigated. For this purpose; camera interior orientation parameters and stereo camera baseline lenght are re-calculated with the advanced adjustment techniques. In this study; “Stereo Photogrammetric Surgical Navigation Software” and “Photogrammetric Camera Calibration Software” which have been developed since 2014 by responsible author are used. As a result of study; it is observed and presented in detail that the calibrated system components have brought the real-time location measurement accuracy from 2-3 mm level to 0,2 mm level.en_US
dc.language.isoturen_US
dc.publisherAfyon Kocatepe Üniversitesien_US
dc.identifier.doi10.35414/akufemubid.851780en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCerrahi Navigasyonen_US
dc.subjectYersel Fotogrametrien_US
dc.subjectKamera Kalibrasyonuen_US
dc.subjectEKK Dengelemeen_US
dc.subjectKonum Doğruluğuen_US
dc.subjectSurgical Navigationen_US
dc.subjectClose-Range Photogrammetryen_US
dc.subjectCamera Calibrationen_US
dc.subjectLeast-Squares Adjustmenten_US
dc.subjectGeolocation Accuracyen_US
dc.titleFotogrametrik cerrahi navigasyon uygulamalarında kamera ve sistem kalibrasyonunun ölçüm doğruluklarına etkisien_US
dc.title.alternativeKamera and system calibration effects on measurement accuracies in photogrammetric surgical navigation applicationsen_US
dc.typearticleen_US
dc.relation.journalFen ve Mühendislik Bilimleri Dergisien_US
dc.departmentAnkara Harita Genel Müdürlüğü, Samsun Üniversitesien_US
dc.authorid0000-0001-9881-339Xen_US
dc.authorid0000-0002-5205-1622en_US
dc.identifier.volume21en_US
dc.identifier.startpage640en_US
dc.identifier.endpage649en_US
dc.identifier.issue3en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster