dc.identifier.citation | Sarpün, İ. H. , Özsoy, C. , Aydın, V. & Koca, T. (2021). Variation of the Absorbed Dose by the Weight of the Patient in CT Scanning . Afyon Kocatepe Üniversitesi Uluslararası Mühendislik Teknolojileri ve Uygulamalı Bilimler Dergisi , 4 (2) , 83-86 . DOI: 10.53448/akuumubd.984623 | en_US |
dc.identifier.uri | https://dergipark.org.tr/tr/pub/akuumubd/issue/64247/984623 | |
dc.identifier.uri | https://hdl.handle.net/11630/10949 | |
dc.description.abstract | Tüm radyoterapi işlemi sırasında çekilen Bilgisayarlı Tomografi (BT) görüntüleri, tedavi portalı tasarımı,
planlaması ve hasta pozisyonunun sağlanması için önemlidir. Ancak bu BT taramalarında hastanın aldığı
doz, planlama doz hesaplamalarına dahil edilmez. Özellikle adaptif tedavilerde kritik organların limit
dozlarının hesaplanmasında günlük BT taramalarından alınan doz çok önemli hale gelmektedir. Bu
çalışmada, Monte Carlo tekniğinin kullanıldığı NCICT kodu ile hastaların bazı kritik organları olan kalp ve
karaciğerin aldığı dozun hastanın ağırlığına göre değişimi araştırıldı. | en_US |
dc.description.abstract | Computed Tomography (CT) images taken during whole radiotherapy procedure is important for
treatment planning, portal design and providing patient position. However, the dose received by the
patient in these CT scans are not included in the planning dose calculations. Especially in adaptive
treatments, the dose received from daily CT scan becomes very important in calculation of the limit
doses of critical organs. In this study, with the NCICT code, which use the Monte Carlo technique, the
change of the dose absorbed by some critical organs of the patients, namely the heart and liver,
according to the weight of the patient, was investigated. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Afyon Kocatepe Üniversitesi | en_US |
dc.identifier.doi | 10.53448/akuumubd.984623 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | BT | en_US |
dc.subject | Fantom | en_US |
dc.subject | NCICT | en_US |
dc.subject | Monte Carlo | en_US |
dc.title | CT taramalarında hastanın kilosuna göre alınan dozun değişimi | en_US |
dc.type | article | en_US |
dc.relation.journal | Uluslararası Mühendislik Teknolojileri ve Uygulamalı Bilimler Dergisi | en_US |
dc.department | Seçiniz | en_US |
dc.authorid | 0000-0002-9788-699X | en_US |
dc.authorid | 0000-0001-8002-2805 | en_US |
dc.authorid | 0000-0003-2277-0922 | en_US |
dc.authorid | 0000-0002-7400-1837 | en_US |
dc.identifier.volume | 4 | en_US |
dc.identifier.startpage | 83 | en_US |
dc.identifier.endpage | 86 | en_US |
dc.identifier.issue | 2 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Başka Kurum Yazarı | en_US |