Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖzbek, Zikriye
dc.date.accessioned2023-09-20T10:11:03Z
dc.date.available2023-09-20T10:11:03Z
dc.date.issued15.06.2023en_US
dc.identifier.citationÖzbek, Z. (2023). Kolesterol Tayini için Biyosensör Geliştirilmesi . Afyon Kocatepe Üniversitesi Uluslararası Mühendislik Teknolojileri ve Uygulamalı Bilimler Dergisi , 6 (1) , 63-74 . DOI: 10.53448/akuumubd.1296685en_US
dc.identifier.urihttps://dergipark.org.tr/tr/pub/akuumubd/issue/76075/1296685
dc.identifier.urihttps://hdl.handle.net/11630/11110
dc.description.abstractBu çalışmada, kolesterol amperometrik tayini için Prusya mavisi (PB) temelli amperometrik biyosensörler hazırlandı. Bu amaçla, jelatin ve gluteraldehit içeren ortam kullanılarak çapraz bağlama tekniği ile PB ve kolesterol oksidaz (COx) enzimi screen-printed elektrotların (SPE) yüzeyine immobilize edildi. SPE/PB/COx elektrotların kolesterol tayini için uygun oldukları gözlendi ve optimizasyon çalışmaları bu enzim elektrotları kullanılarak yapıldı. SPE/PB/COx enzim elektrodu için optimum jelatin miktarı, gluteraldehit oranı, PB derişimi, tampon cinsi, tampon derişimi, sırasıyla fosfat tamponu; 0,002 g, % 0.5, 0.02 M, 0.05 M; pH:7,5 olarak belirlendi. Enzim elektrodun, kolesterol için doğrusal çalışma aralığı 2×10-6 -2×10-5 M, gözlenebilme sınırı 2×10-6 M, cevap süresi 50 s ve raf ömrü yaklaşık bir ay olarak bulundu. SPE/PB/COX kolesterol biyosensörü hazırlanması optimizasyonu başarılı bir şekilde elde edildi.en_US
dc.description.abstractIn this study, for the determination of cholesterol amperometric Prussian blue (PB) based amperometric biosensors were prepared. For this purpose, the cross-linking techniques using glutaraldehyde medium containing gelatin and PB and cholesterol oxidase (COX) enzyme was immobilized on the surface of the screen-printed electrode. SPE / PB / COX was observed that the electrodes are suitable for the determination of cholesterol and optimization study was performed using the enzyme electrodes. SPE / PB / COX enzyme optimum amount of gelatin to the electrodes, glutaraldehyde ratio of concentration, buffer type, buffer concentration, respectively, in phosphate buffer; 0.002 g, 0.5%, 0.02 M, 0.05 M; pH was set at 7.5. The enzyme electrode linear operating range for cholesterol, 2 × 10-6 -2 × 10-5 M, observed ability to limit 2 × 10-6 M, response time of 50 h and shelflife was found to be about a month. Optimization of SPE/PB/COX cholesterol biosensor preparation was successfully achieved.en_US
dc.language.isoturen_US
dc.publisherAfyon Kocatepe Üniversitesien_US
dc.identifier.doi10.53448/akuumubd.1296685en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAmperometrien_US
dc.subjectBiyosensören_US
dc.subjectEnzim Elektroten_US
dc.subjectKolesterolen_US
dc.subjectAmperometryen_US
dc.subjectBiosensoren_US
dc.subjectEnzyme Electrodeen_US
dc.subjectCholesterolen_US
dc.titleKolesterol tayini için biyosensör geliştirilmesien_US
dc.typearticleen_US
dc.relation.journalUluslararası Mühendislik Teknolojileri ve Uygulamalı Bilimler Dergisien_US
dc.departmentSeçinizen_US
dc.authorid0000-0002-9112-1478en_US
dc.identifier.volume6en_US
dc.identifier.startpage63en_US
dc.identifier.endpage74en_US
dc.identifier.issue1en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarıen_US