dc.description.abstract | Bu çalışmada, kolesterol amperometrik tayini için Prusya mavisi (PB) temelli amperometrik
biyosensörler hazırlandı. Bu amaçla, jelatin ve gluteraldehit içeren ortam kullanılarak çapraz bağlama
tekniği ile PB ve kolesterol oksidaz (COx) enzimi screen-printed elektrotların (SPE) yüzeyine immobilize
edildi. SPE/PB/COx elektrotların kolesterol tayini için uygun oldukları gözlendi ve optimizasyon
çalışmaları bu enzim elektrotları kullanılarak yapıldı. SPE/PB/COx enzim elektrodu için optimum jelatin
miktarı, gluteraldehit oranı, PB derişimi, tampon cinsi, tampon derişimi, sırasıyla fosfat tamponu; 0,002
g, % 0.5, 0.02 M, 0.05 M; pH:7,5 olarak belirlendi. Enzim elektrodun, kolesterol için doğrusal çalışma
aralığı 2×10-6
-2×10-5 M, gözlenebilme sınırı 2×10-6 M, cevap süresi 50 s ve raf ömrü yaklaşık bir ay olarak
bulundu. SPE/PB/COX kolesterol biyosensörü hazırlanması optimizasyonu başarılı bir şekilde elde edildi. | en_US |
dc.description.abstract | In this study, for the determination of cholesterol amperometric Prussian blue (PB) based
amperometric biosensors were prepared. For this purpose, the cross-linking techniques using
glutaraldehyde medium containing gelatin and PB and cholesterol oxidase (COX) enzyme was
immobilized on the surface of the screen-printed electrode. SPE / PB / COX was observed that the
electrodes are suitable for the determination of cholesterol and optimization study was performed
using the enzyme electrodes. SPE / PB / COX enzyme optimum amount of gelatin to the electrodes,
glutaraldehyde ratio of concentration, buffer type, buffer concentration, respectively, in phosphate
buffer; 0.002 g, 0.5%, 0.02 M, 0.05 M; pH was set at 7.5. The enzyme electrode linear operating range
for cholesterol, 2 × 10-6
-2 × 10-5 M, observed ability to limit 2 × 10-6 M, response time of 50 h and shelflife was found to be about a month. Optimization of SPE/PB/COX cholesterol biosensor preparation was
successfully achieved. | en_US |
dc.language.iso | tur | en_US |
dc.publisher | Afyon Kocatepe Üniversitesi | en_US |
dc.identifier.doi | 10.53448/akuumubd.1296685 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Amperometri | en_US |
dc.subject | Biyosensör | en_US |
dc.subject | Enzim Elektrot | en_US |
dc.subject | Kolesterol | en_US |
dc.subject | Amperometry | en_US |
dc.subject | Biosensor | en_US |
dc.subject | Enzyme Electrode | en_US |
dc.subject | Cholesterol | en_US |
dc.title | Kolesterol tayini için biyosensör geliştirilmesi | en_US |
dc.type | article | en_US |
dc.relation.journal | Uluslararası Mühendislik Teknolojileri ve Uygulamalı Bilimler Dergisi | en_US |
dc.department | Seçiniz | en_US |
dc.authorid | 0000-0002-9112-1478 | en_US |
dc.identifier.volume | 6 | en_US |
dc.identifier.startpage | 63 | en_US |
dc.identifier.endpage | 74 | en_US |
dc.identifier.issue | 1 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Başka Kurum Yazarı | en_US |