dc.identifier.citationDepboylu, F. N. , Poyraz, Ö. , Yasa, E. & Korkusuz, F. (2023). Lazer-Toz Yatağında Füzyon ile Üretilen Ti6Al4V Gyroid Yapıların Basma Dayanımlarının Nümerik Modellenmesi . Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi , 23 (1) , 270-283 . DOI: 10.35414/akufemubid.1171673en_US
dc.identifier.urihttps://doi.org/10.35414/akufemubid.1171673
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/2635363
dc.identifier.urihttps://hdl.handle.net/11630/11252
dc.description.abstractOrtopedik metal implantlar fonksiyonun geri kazanılması amacıyla eklem ve kemik dokusunun onarımı sürecinde sağlamlığı korumak için yaygın kullanılır. İmplantların yük taşıma işlevi gören bölgeye uygun elastik modül değeri ve vücutta oluşacak olumsuz etkileri önleyici biyouyumluluk özelliklerinin olması, minimum gereksinimlerdir. İdeal implant malzemesi üzerine yaygınlaşmış çalışmalar, yüksek mekanik dayanıklılık ve osteointegrasyon özellikleri nedeniyle titanyum ve titanyum alaşımlı implantlar üzerinedir. Ancak implantasyon sonrası vücutta kalması istenen durumlarda biyoaktiviteyi daha da artırmak ve kemiğin mekanik özelliklerine yaklaşmak amacıyla üçlü periyodik minimal yüzey (ÜPMY) kafes yapısına sahip gözenekli implantlar kullanılır. Çalışma, istenen mekanik özellikleri ve gözenekler arası hücre hareketini sağlamak için kontrollü ÜPMY kafes yapılarından gyroid gözenek yapısına sahip lazer toz yatağında füzyon ile üretimi planlanan Ti6Al4V ilk olarak 40-80% arasında farklı gözeneklilik oranlarında tasarlanmıştır. Ardından her bir tasarım için basma altında mekanik dayanım ve deformasyon davranışlarını sonlu eleman analizi altında incelemeye odaklanılmıştır. Literatüre bakıldığında lazer toz yatağında füzyon ile üretilen gyroid Ti6Al4V yapıların basma testi sonuçları ile karşılaştırılmış ve uyumlu sonuçlar alınmıştır.en_US
dc.description.abstractMetal orthopedic implants are widely used to maintain stability during tissue repair in joint and bone injuries to restore function. Elastic modulus values suitable for the area where the implants carry the load-bearing part and have biocompatibility features that prevent harmful effects on the body are the minimum requirements. Widespread studies on the ideal implant material are on titanium and titanium alloy implants due to their high mechanical strength and osteointegration properties. However, in cases where it is desired to remain in the body after implantation, porous implants with triply periodic minimal surface (TPMS) lattice structures are used in order to increase the bioactivity further and reach the mechanical properties of the bone. In the study, Ti6Al4V with gyroid pore structure, one of the controlled TPMS lattice structures planned to be produced by laser powder bed fusion technology, was designed with different porosity rates between 40-80%. Then, the focus is on examining the mechanical strength and deformation behaviors under compression for each design with the finite element analysis. The results of the study were compared with the compression test of gyroid Ti6Al4V structures produced by laser powder bed fusion from the literature and consistent results were obtained.en_US
dc.language.isoengen_US
dc.publisherAfyon Kocatepe Üniversitesien_US
dc.identifier.doi10.35414/akufemubid.1171673en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSonlu Elemanlar Analizien_US
dc.subjectGyroid Kafesen_US
dc.subjectYapı Tasarımıen_US
dc.subjectOrtopedik İmplanten_US
dc.subjectTitanyumen_US
dc.subjectÜçlü Periyodiken_US
dc.subjectMinimal Yüzeyleren_US
dc.subjectFinite Element Analysisen_US
dc.subjectGyroid Latticeen_US
dc.subjectStructure Designen_US
dc.subjectOrthopedic Implanten_US
dc.subjectTitaniumen_US
dc.subjectTriply Periodicen_US
dc.subjectMinimal Surfacesen_US
dc.titleLazer-toz yatağında füzyon ile üretilen ti6al4v gyroid yapıların basma dayanımlarının nümerik modellenmesen_US
dc.title.alternativeNumerical modeling of compression strengths of ti6al4v gyroid structures produced by laser powder bed fusion technologyen_US
dc.typearticleen_US
dc.relation.journalAfyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisien_US
dc.departmentAfyon Kocatepe Üniversitesien_US
dc.authorid0000-0003-0401-5923en_US
dc.authorid0000-0001-9892-5738en_US
dc.authorid0000-0001-5443-3598en_US
dc.authorid0000-0001-9486-3541en_US
dc.identifier.volume23en_US
dc.identifier.startpage270en_US
dc.identifier.endpage283en_US
dc.identifier.issue1en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster