Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorArslan, Muhammed
dc.contributor.authorYılmaz, Ceyhun
dc.date.accessioned2025-02-10T10:25:45Z
dc.date.available2025-02-10T10:25:45Z
dc.date.issued15.09.2022en_US
dc.identifier.citationARSLAN, M., & YILMAZ, C. (2022). Design and optimization of multigeneration biogas power plant using waste heat recovery System A case study with Energy Exergy and thermoeconomic approach of Power cooling and heating. Fuel, 324, 0–0.en_US
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0016236122016246
dc.identifier.urihttps://hdl.handle.net/11630/12235
dc.description.abstractThis study modeled and analyzed transforming an operational biogas power plant into a trigeneration system with power, cooling, and heating. In this context, the energy, exergy, and optimum unit energy costs of this trigeneration system's power, cooling, and heating are investigated. The transformation of the clean energy potential of Afyonkarahisar city as biogas into power is investigated and analyzed by realizing it on an established biogas power plant. The high-temperature exhaust gases from the power unit (PU) are directed to the generator of an absorption cooling system, operating the cooling unit (CU). Exhaust gases from the generator, which are still hot, start a heating unit (HU) for space heating and are released into the atmosphere. As a result of the optimization, The energy efficiency, exergy efficiency, fuel consumption, and unit electricity cost of the existing power plant are 39.54%, 34.65%, 0.3161 kg/s, and 0.042 $/kWh. By integrating the optimized cooling unit to power unit, energy efficiency, exergy efficiency, and unit cooling cost of the plant were 54.2%, 43.39%, and 0.0352 $/kWh. Finally, with the integration of the heating unit to the plant, energy efficiency, exergy efficiency, and unit heating cost of the plant were 74.2%, 50.14%, and 0.0178 $/kWh, respectively.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.identifier.doihttps://doi.org/10.1016/j.fuel.2022.124779en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiogas Planten_US
dc.subjectHeating and Coolingen_US
dc.subjectOptimizationen_US
dc.subjectThermodynamicen_US
dc.subjectThermoeoconomicen_US
dc.titleDesign and optimization of multigeneration biogas power plant using waste heat recovery System: A case study with Energy, Exergy, and thermoeconomic approach of Power, cooling and heatingen_US
dc.typearticleen_US
dc.relation.journalFuelen_US
dc.departmentMeslek Yüksekokulları, Çay Meslek Yüksekokulu, Otomotiv Teknolojisi Programıen_US
dc.authorid0000-0001-8387-7008en_US
dc.authorid0000-0002-8827-692Xen_US
dc.identifier.volume324en_US
dc.identifier.startpage124779en_US
dc.identifier.issuePart Cen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorArslan, Muhammed
dc.contributor.institutionauthorYılmaz, Ceyhun