Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorİnan, Ümit Übeyt
dc.contributor.authorTümer, Erhan
dc.contributor.authorYavaş, Güliz
dc.contributor.authorKüsbeci, Tuncay
dc.contributor.authorİnan, Sibel
dc.contributor.authorErmiş, Sıtkı Samet
dc.date2015-02-11
dc.date.accessioned2015-02-11T13:15:11Z
dc.date.available2015-02-11T13:15:11Z
dc.date.issued2011-09
dc.identifier.issn1302-4612
dc.identifier.urihttp://hdl.handle.net/11630/1976
dc.description.abstractAmaç: Çalışmamızda 23 gauge transkonjonktival pars plana vitrektomi tekniği ile vitreoretinal cerrahi uygulanan hastaların, xenon ışık kaynağı kullanılarak yapılan ameliyatlarının geriye dönük olarak incelenerek ameliyat süresi, anatomik başarı ve komplikasyonların incelenmesi amaçlanmaktadır. Gereç yöntem: Afyon Kocatepe Üniversitesi Tıp Fakültesi Göz Hastalıkları Anabilim Dalında Ocak 2010 ile Aralık 2010 tarihleri arasında, Xenon ışık kaynağı kullanılarak gerçekleştirilen 23 gauge pars plana vitrektomi ameliyatı yapılan 135 hastanın 135 gözü çalışmaya dahil edildi. Yirmi üç gauge pars plana vitrektomi tekniği ile vitreoretinal cerrahi uygulanan hastaların kayıtları geriye dönük olarak incelenerek hastaların yaş, cinsiyet, ameliyat endikasyonları, anestezi şekli, anatomik başarı, cerrahinin süresi, gelişen komplikasyonlar, kullanılan göz içi tamponat türü araştırıldı. Bulgular: Hastaların 62’si (% 45.9) erkek, 73’ü (% 54.1) kadındı. Yaş ortalaması 52.4±12.23 yıl idi. Xenon ışık kaynağı kullanılarak gerçekleştirilen 23 gauge pars plana vitrektomi ameliyatı yapılan hastalarda anatomik başarı oranı yüksek olup 134 hastada anatomik başarı elde edilmiş, yalnızca 1 gözde anatomik başarı sağlanamadı. Ortalama ameliyat süresi 65.56±25.78 dakika idi. Gerçekleştirilen pars plana vitrektomi ameliyatlarının 58’inde (% 43) herhangi bir retinal tamponat kullanılmayıp, geri kalan ameliyatlarda kullanılan göz içi tamponatlar ise; 46 (% 34) hastada silikon, 11 (% 8.1) hastada hava, 10 (% 7.4) hastada C3F8 gazı ve 10 (% 7.4) hastada SF6 gazıydı. Xenon ışık kaynağı kullanılarak gerçekleştirilen 23 gauge pars plana vitrektomi ameliyatı yapılan hastalarda ameliyat esnasında gelişen komplikasyonlar 10 (% 7.4) hastada iatrojenik retinal yırtık, 1 (% 0.7) hastada koroid dekolmanı ve 1 (% 0.7) hastada suprakoroidal hemoraji idi. Geriye kalan 123 (% 91) hastanın ameliyatı esnasındaysa herhangi bir komplikasyon gelişmedi. Hiçbir hastada anesteziye bağlı bir komplikasyona rastlanmadı. Sonuç: Xenon ışık kaynağı, ciddi intraoperatif komplikasyonlar gelişmeksizin daha kısa süreler içinde 23 gauge transkonjonktival pars plana vitrektominin yapılabilmesi için yeterli aydınlanma ile yüksek görüntü kalitesi sağlayabilir.en_US
dc.description.abstractPurpose: In our study we aimed to evaluate retrospectively the operation time, anatomical success and complications in patients undergoing vitreoretinal surgery with 23 gauge transconjunctival pars plana vitrectomy technique using xenon light source Material and Methods: One hundred thirty five eyes of 135 patients undergoing 23 gauge transconjunctival pars plana vitrectomy using XENON light source were included into the study between the January 2010 and December 2010 in the Kocatepe University Department of Ophthalmology. After the retrospective review of the files of all the patients who underwent vitreoretinal surgery with 23 gauge transconjunctival pars plana vitrectomy, age, gender, indication for surgery, type of anesthesia, anatomical success, operation time, complications, and type of intraocular tamponade were analyzed. Results: Patients were consisted of 62 men (45.9%) and 73 women (54.1%). Mean age was 52.4±12.23 years. The anatomical success rate in patients who have underwent 23 gauge transconjuntival pars plana vitrectomy with XENON light source was quite high with 134 patients who had achieved anatomically successful outcome except one patient in whom anatomical success could not be obtained. Mean operation time was 65.56±25.78 minute. In 58 (43%) of operations, any intraocular tamponade was not used. In the remaining eyes, silicon tamponade was used in 46 eyes (34%), air in 11 eyes (8.1%), C3F8 gas in 10 eyes (7.4%) and SF6 gas in 10 eyes (7.4%). The complications developed during the pars plana vitrectomy using XENON light source were iatrogenic retinal tear in 10 patient (7.4%), choroid detachment in one patient (0.7%), suprachoroidal hemorrhage in one patient (0.7%). In the remaining eyes (91%), no complication developed during the operation. No anesthesia related complication occurred in none of the patients. Conclusion: XENON light source may provide sufficient illumination with higher quality of image to perform 23 gauge small incision transconjunctival pars plana vitrectomy within shorter operation times by avoiding severe intraoperative complications.
dc.language.isoturen_US
dc.publisherAfyon Kocatepe Üniversitesi, Kocatepe Tıp Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject23 g Vitrektomien_US
dc.subjectSütürsüz Küçük Kesien_US
dc.subjectXenonen_US
dc.subjectHalojenen_US
dc.subjectIşık Kaynağıen_US
dc.titleVitreoretinal cerrahide xenon ışık aydınlatmanın etkilerien_US
dc.title.alternativeThe efficacy of xenon light endoillumination on vitreoretinal surgeryen_US
dc.typearticleen_US
dc.relation.journalAfyon Kocatepe Üniversitesi, Kocatepe Tıp Dergisien_US
dc.departmentAfyon Kocatepe Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalıen_US
dc.identifier.volume12en_US
dc.identifier.startpage137en_US
dc.identifier.endpage143en_US
dc.identifier.issue3en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Yayınıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

  • Makaleler [452]
    Makale, olgu sunumu, editöre mektup vb.