dc.description.abstractBu çalışmada veteriner hekimlikte sıklıkla kullanılan hücre sayımı temel prensipli ve amperometrik yöntem ile ölçüm yapan iki farklı hematokrit ölçüm tekniğinin karşılaştırılması amaçlandı. Farklı etiyolojileri bulunan her iki cinsiyetten toplam 84 neonatal ishalli buzağı çalışmaya dahil edildi. Hematokrit ölçümleri için buzağılardan lityum heparin içeren kan gazı enjektörlerine ve tüplere kan örnekleri, toplamda 4 ml olacak şekilde alındı. Hematokrit ölçümleri için Abacus Junior Vet 5 kan sayım cihazı ve Irma Truepoint kan gazı analiz cihazından yararlanıldı. Linear regresyon analizi ve pearson korelasyonu sonuçlarına göre hematokrit ölçümlerinden elde edilen verilerin her iki ölçüm tekniği arasında r=0.90 (p<0.000) düzeyinde pozitif yönde korelasyona sahip olduğu, ancak iki test tekniğinin ortalama değerleri arasında istatistiksel yönden farklılıkların bulunduğu belirlendi. Passing-bablok regresyon analizinde ise y= 0.88x+1.81 denklemi elde edildi. Çalışma sonuçlarına göre, klinikte yoğun şekilde yapılan hematokrit ölçümlerinin değerlendirilmesinde her iki ölçüm tekniğinden yararlanılabileceği ancak iki ölçüm metodu arasında farklılıkların bulunmasına bağlı olarak hasta hayvanlarda şüpheye düşüldüğü durumlarda klasik santrifüj yöntemine dayalı mikrohematokrit ölçümlerinin yapılması gerektiği sonucuna varıldı.en_US
dc.description.abstractIn this study, it was aimed to compare two different hematocrit measurement techniques which are commonly used in veterinary medicine by cell count, and amperometric method. A total of 84 neonatal diarrheic calves from both sexes with different etiologies were included in the study. For hematocrit measurements, blood samples (4 ml) were taken to blood gas injectors and tubes containing lithium heparin from calves. The Abacus Junior Vet 5 whole blood cell counter and Irma True Point blood gas analyzer were used for hematocrit measurements. According to the results of linear regression analysis and Pearson correlation, it was determined that the data obtained from the hematocrit measurements had positive correlations between r = 0.90 (p <0.000) between the two measurement techniques, but statistically significant differences were found between the mean values of the two test techniques. In Passing-bablok analysis y= 0.88x+1.81 equation was found. According to the results, both measurements can be utilized in assessing hematocrit measurement, but in case of the difference between the two measuring methods, it was concluded that suspected cases should be made based on the conventional measurement microhematocrit centrifugation.
dc.language.isoturen_US
dc.identifier.doi10.5578/kvj.66212en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBuzağıen_US
dc.subjectHematokrit
dc.subjectİshal
dc.subjectÖlçüm Tekniği
dc.subjectPassing-Bablok
dc.subjectCalf
dc.subjectHematocrit
dc.subjectDiarrhoea
dc.subjectMeasurement Technique
dc.subjectPassing-Bablok
dc.titleNeonatal ishalli buzağılarda iki farklı hematokrit ölçüm tekniğinin karşılaştırılmasıen_US
dc.title.alternativeComparison of two hematocrite measurement methods in diarrheic neonatal calvesen_US
dc.typearticleen_US
dc.relation.journalKocatepe Veteriner Dergisien_US
dc.departmentAydın Adnan Menderes Üniversitesi, Veteriner Fakültesien_US
dc.identifier.volume11en_US
dc.identifier.startpage24en_US
dc.identifier.endpage29en_US
dc.identifier.issue1en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Yayınıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster