Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorBüyüksağiş, Aysel
dc.contributor.authorErol, Sinem
dc.date.accessioned2019-12-20T16:41:34Z
dc.date.available2019-12-20T16:41:34Z
dc.date.issued2013en_US
dc.identifier.citationBüyüksağiş, Aysel & Erol, Sinem; The Examination of Afyonkarahisar’s Jeothermal System Corrosion”, Journal of Materials Engineering and Performance,2013, Vol.22, pp:563-573en_US
dc.identifier.urihttps://www.doi.org/10.1007/s11665-012-0252-x
dc.identifier.urihttps://hdl.handle.net/11630/7597
dc.description.abstractCorrosion and scaling of metal surfaces are the major problems caused by geothermal fluids when metallic structures are used. This article describes a study of corrosion and scaling problems in the Afyonkarahisar Geothermal Heating System (AFJET) in Afyonkarahisar, Turkey. Water analysis, XRD, SEM, EDX, IC, ICP-OES analyses, and electrochemical methods were used in this study. Pentasodium triphosphate (Na5P3O10), maleic anhydride (C4H2O3), and 1,3-benzendisulfonic acid disodium salt (C6H4Na2O6S2) were used as corrosion inhibitors. Tests were carried out using geothermal water from AF11 well. The experimental temperatures were chosen as 298, 333, and 358 K. Inhibitor concentrations were chosen as 131021, 131022, 131023, and 131024 mol/dm3. Moreover, mixed inhibitor solutions were prepared using the inhibitor concentrations that showed the best inhibition. The first mixed inhibitor solution showed 96% inhibition. The second mixed inhibitor solution showed 90% inhibition. The tested inhibitors act as anodic inhibitors. XRD analysis shows that there is CaCO3 aragonite scaling in the system. Increasing TDS, alkalinity, and hardness all promote scale formation. The photomicrographs from SEM-EDX and the metallographic microscope show that the tested inhibitors form a protective film on the surface. IC and ICP-OES analyses show that the concentration of Ca2+ is very high, which supports scale formation.en_US
dc.language.isoengen_US
dc.publisherASM Internationalen_US
dc.identifier.doi10.1007/s11665-012-0252-xen_US
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_US
dc.subjectCorrosionen_US
dc.subjectInhibitoren_US
dc.subjectScaleen_US
dc.subjectXRDen_US
dc.subjectGeothermal Fluiden_US
dc.titleThe examination of Afyonkarahisar's geothermal system corrosionen_US
dc.typearticleen_US
dc.relation.journalJournal of Materials Engineering and Performanceen_US
dc.departmentFen-Edebiyat Fakültesien_US
dc.authorid0000-0001-8911-7157en_US
dc.identifier.volume22en_US
dc.identifier.startpage563en_US
dc.identifier.endpage573en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorBüyüksağiş, Aysel


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster