dc.contributor.author | Talay Pınar, Pınar | |
dc.contributor.author | Yardım, Yavuz | |
dc.date.accessioned | 2021-09-30T11:48:44Z | |
dc.date.available | 2021-09-30T11:48:44Z | |
dc.date.issued | 17.03.2020 | en_US |
dc.identifier.citation | Talay Pınar, P. & Yardım, Y. (2020). Katyonik Surfaktan Varlığında Kalem Grafit Elektrot Yüzeyinde Epirubisin’in Sıyırma Voltametrisi ile Miktar Tayini . Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi , 20 (1) , 19-29 . DOI: 10.35414/akufemubid.621530 | en_US |
dc.identifier.uri | https://dergipark.org.tr/tr/pub/akufemubid/issue/53078/621530 | |
dc.identifier.uri | https://doi.org/10.35414/akufemubid.621530 | |
dc.identifier.uri | https://hdl.handle.net/11630/9307 | |
dc.description.abstract | Bu çalışmada, bir antrasiklin ilaç olan epirubisin’in, kalem grafit elektrot kullanarak elektrokimyasal özelliklerini katyonik surfaktan varlığında Britton-Robinson tampon çözeltisinde (pH 2.0-10.0) araştırılmıştır. Öncelikle kalem grafit elektrotun performansını etkileyen parametreler örneğin, elektrot aktivasyonu, destek elektrolit seçimi, pH etkisi, biriktirme gerilimi ve süresi, surfaktan etkisi ve kare-dalga voltametrik yöntem parametreleri adsorptif sıyırma voltametrisi tekniği kullanılarak detaylı bir şekilde incelenmiştir. Daha sonra önerilen tekniklerin elde edilen en iyi koşullarında epirubisin için doğrusal aralık (0.01-2.0 μg mL-1) ve gözlenebilme sınırı (GS; 0.0018 μg mL-1) belirlenmiştir. Geliştirilen kare dalga adsorptif sıyırma voltametri tekniği, insan idrarına standart katma tekniğiyle uygulanmıştır. | en_US |
dc.description.abstract | In this study, the electrochemical properties of epirubicin, an anthracycline drug using pencil graphite electrode, were investigated in Britton-Robinson buffer (pH 2.0-10.0) in the presence of cationic surfactant. Firstly, parameters affecting the performance of the pencil graphite electrode, such as electrode activation, support electrolyte selection, pH effect, deposition voltage and duration, surfactant effect, and square-wave voltammetric method parameters were investigated in detail by using adsorptive stripping voltammetry technique. Then, the linearity of epirubicin (0.01-2.0 μg mL-1) was determined as the detection limit (LOD; 0.0018 μg mL-1) in the best conditions obtained in the proposed techniques. The developed square wave adsorptive stripping voltammetry technique was applied to the human urine with standard addition technique. | en_US |
dc.language.iso | tur | en_US |
dc.publisher | Afyon Kocatepe Üniversitesi | en_US |
dc.identifier.doi | 10.35414/akufemubid.621530 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Epirubisin | en_US |
dc.subject | Katyonik Surfaktan | en_US |
dc.subject | Voltametri | en_US |
dc.subject | Biyolojik Örnek | en_US |
dc.subject | Kalem | en_US |
dc.subject | Grafit | en_US |
dc.subject | Elektrot | en_US |
dc.subject | Epirubicin | en_US |
dc.subject | Cationic Surfactant | en_US |
dc.subject | Voltammetry | en_US |
dc.subject | Pencil | en_US |
dc.subject | Graphite Electrode | en_US |
dc.subject | Biological Sample | en_US |
dc.title | Katyonik surfaktan varlığında kalem grafit elektrot yüzeyinde epirubisin’in sıyırma voltametrisi ile miktar tayini | en_US |
dc.title.alternative | Voltammetric determination of epirubicin using a pencil graphite electrode in the presence of cationic surfactant | en_US |
dc.type | article | en_US |
dc.relation.journal | Afyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisi | en_US |
dc.department | Seçiniz | en_US |
dc.authorid | 0000-0003-1027-1456 | en_US |
dc.authorid | 0000-0002-9587-0966 | en_US |
dc.identifier.volume | 20 | en_US |
dc.identifier.startpage | 19 | en_US |
dc.identifier.endpage | 29 | en_US |
dc.identifier.issue | 1 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Başka Kurum Yazarı | en_US |