Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorTalay Pınar, Pınar
dc.contributor.authorYardım, Yavuz
dc.date.accessioned2021-09-30T11:48:44Z
dc.date.available2021-09-30T11:48:44Z
dc.date.issued17.03.2020en_US
dc.identifier.citationTalay Pınar, P. & Yardım, Y. (2020). Katyonik Surfaktan Varlığında Kalem Grafit Elektrot Yüzeyinde Epirubisin’in Sıyırma Voltametrisi ile Miktar Tayini . Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi , 20 (1) , 19-29 . DOI: 10.35414/akufemubid.621530en_US
dc.identifier.urihttps://dergipark.org.tr/tr/pub/akufemubid/issue/53078/621530
dc.identifier.urihttps://doi.org/10.35414/akufemubid.621530
dc.identifier.urihttps://hdl.handle.net/11630/9307
dc.description.abstractBu çalışmada, bir antrasiklin ilaç olan epirubisin’in, kalem grafit elektrot kullanarak elektrokimyasal özelliklerini katyonik surfaktan varlığında Britton-Robinson tampon çözeltisinde (pH 2.0-10.0) araştırılmıştır. Öncelikle kalem grafit elektrotun performansını etkileyen parametreler örneğin, elektrot aktivasyonu, destek elektrolit seçimi, pH etkisi, biriktirme gerilimi ve süresi, surfaktan etkisi ve kare-dalga voltametrik yöntem parametreleri adsorptif sıyırma voltametrisi tekniği kullanılarak detaylı bir şekilde incelenmiştir. Daha sonra önerilen tekniklerin elde edilen en iyi koşullarında epirubisin için doğrusal aralık (0.01-2.0 μg mL-1) ve gözlenebilme sınırı (GS; 0.0018 μg mL-1) belirlenmiştir. Geliştirilen kare dalga adsorptif sıyırma voltametri tekniği, insan idrarına standart katma tekniğiyle uygulanmıştır.en_US
dc.description.abstractIn this study, the electrochemical properties of epirubicin, an anthracycline drug using pencil graphite electrode, were investigated in Britton-Robinson buffer (pH 2.0-10.0) in the presence of cationic surfactant. Firstly, parameters affecting the performance of the pencil graphite electrode, such as electrode activation, support electrolyte selection, pH effect, deposition voltage and duration, surfactant effect, and square-wave voltammetric method parameters were investigated in detail by using adsorptive stripping voltammetry technique. Then, the linearity of epirubicin (0.01-2.0 μg mL-1) was determined as the detection limit (LOD; 0.0018 μg mL-1) in the best conditions obtained in the proposed techniques. The developed square wave adsorptive stripping voltammetry technique was applied to the human urine with standard addition technique.en_US
dc.language.isoturen_US
dc.publisherAfyon Kocatepe Üniversitesien_US
dc.identifier.doi10.35414/akufemubid.621530en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectEpirubisinen_US
dc.subjectKatyonik Surfaktanen_US
dc.subjectVoltametrien_US
dc.subjectBiyolojik Örneken_US
dc.subjectKalemen_US
dc.subjectGrafiten_US
dc.subjectElektroten_US
dc.subjectEpirubicinen_US
dc.subjectCationic Surfactanten_US
dc.subjectVoltammetryen_US
dc.subjectPencilen_US
dc.subjectGraphite Electrodeen_US
dc.subjectBiological Sampleen_US
dc.titleKatyonik surfaktan varlığında kalem grafit elektrot yüzeyinde epirubisin’in sıyırma voltametrisi ile miktar tayinien_US
dc.title.alternativeVoltammetric determination of epirubicin using a pencil graphite electrode in the presence of cationic surfactanten_US
dc.typearticleen_US
dc.relation.journalAfyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisien_US
dc.departmentSeçinizen_US
dc.authorid0000-0003-1027-1456en_US
dc.authorid0000-0002-9587-0966en_US
dc.identifier.volume20en_US
dc.identifier.startpage19en_US
dc.identifier.endpage29en_US
dc.identifier.issue1en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Başka Kurum Yazarıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster