dc.contributor.authorCüce, Erdem
dc.date.accessioned2021-10-20T07:12:22Z
dc.date.available2021-10-20T07:12:22Z
dc.date.issued30.11.2020en_US
dc.identifier.citationCuce, E. (2020). Boyuna Uzatılmış Yüzeylerde Dikdörtgensel Oyukların Isı Atımına Etkisi: Bir Hesaplamalı Akışkanlar Dinamiği Analizi . Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi , 20 (5) , 931-940 . DOI: 10.35414/akufemubid.714367en_US
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/1036005
dc.identifier.urihttps://doi.org/10.35414/akufemubid.714367
dc.identifier.urihttps://hdl.handle.net/11630/9547
dc.description.abstractBu çalışmada, üç farklı zorlanmış taşınım koşulu için (h = 25, 50 ve 100 W/m2K) konvansiyonel ve oyuklu kanatlardan olan ısı transferi ANSYS FLUENT yazılımı ile incelendi ve analizler çeşitli oyuk seviyeleri için tekrarlandı. Analizlerde kanat malzemesi olarak 202.4 W/mK ısıl iletkenliğe sahip alüminyum kullanıldı. Operasyonel durum için fotovoltaik sistemlerin zorlanmış taşınımla soğutulması durumu göz önüne alındı ve bu bağlamda, kanat taban sıcaklığı, standart test koşullarını (1000 W/m2 ışınım akısı, 298.15 K çevre sıcaklığı) göz önünde bulundurarak 353.15 K seçildi. Sürekli rejim koşullarında kanat boyunca enerji denklemi .... = 10^−9 yakınsama kriteri ile çözüldü. Çalışmada dikkate alınan referans kanat profili 50 mm boy, 10 mm yükseklik ve 1 mm kalınlık ölçülerine sahiptir. Kanat boyunca boylamasına 1 mm2 ’lik oyuk çiftleri (λ) oluşturuldu ve her bir λ değeri için konvansiyonel ve oyuklu kanatlardan olan ısı atımları sayısal olarak belirlendi. Kanat verimi oyuk seviyesinin bir fonksiyonu olarak ayrıca hesaplandı. Sayısal sonuçlar, artan λ değeri ile kanattan olan ısı atımının azaldığını, ancak bütün taşınım koşulları için, belirli bir λ değerinden sonra birim kanat hacminden olan ısı atımının konvansiyonel kanata kıyasla daha fazla olduğunu gösterdi. Düşük h değerlerinde oyuk etkilerinin daha belirgin olduğu görüldü. h = 25 W/m2K için konvansiyonel kanattan olan ısı atımı 2.5032 W iken, λ = 24 için oyuklu kanattan olan ısı atımı 2.6683 W olarak belirlendi. Bu durum ısı atımında yaklaşık %6.6’lık bir iyileşmeye karşılık gelmektedir.en_US
dc.description.abstractIn this study, for three different forced convection conditions (h = 25, 50 and 100 W/m2K), heat transfer through conventional and perforated fins has been investigated by ANSYS FLUENT software, and the analyses have been repeated for various perforation levels. Aluminium has been utilised as the fin material in the analyses with a thermal conductivity of 202.4 W/mK. For the operational case, cooling of photovoltaic systems by forced convection has been considered, and in this respect, fin base temperature has been selected to be 353.15 K by taking standard test conditions (1000 W/m2 solar intensity, 298.15 K ambient temperature) into consideration. For steady-state conditions, energy equation has been solved along the fin for the convergence criterion of .... = 10^−9 . Reference fin profile considered in the research has a 50 mm length, 10 mm height and 1 mm width. Perforation pairs (λ) of 1 mm2 have been formed longitudinally along the fin and the heat dissipations from conventional and perforated fins have been numerically determined for each λ value. Fin efficiency has also been calculated as a function of perforation level. Numerical results have revealed that heat transfer from the fin decreases with increasing λ value, however for each convection condition, heat dissipation per fin volume from the perforated fin is greater in comparison to the conventional fin after a certain λ value. Perforation effects have been found more noticeable for the lower h values. For h = 25 W/m2K, heat dissipation from the conventional fin has been determined to be 2.5032 W whereas the heat transfer through the perforated fin has been found to be 2.6683 W. This case corresponds to an enhancement of about 6.6% in heat dissipation.en_US
dc.language.isoturen_US
dc.publisherAfyon Kocatepe Üniversitesien_US
dc.identifier.doi10.35414/akufemubid.714367en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIsı transferien_US
dc.subjectUzatılmış yüzeyen_US
dc.subjectBoyuna oyuken_US
dc.subjectKanat verimien_US
dc.subjectKanat hacmi başına ısı atımıen_US
dc.subjectHeat transferen_US
dc.subjectExtended surfaceen_US
dc.subjectLongitudinal perforationen_US
dc.subjectFin efficiencyen_US
dc.subjectHeat dissipation per fin volumeen_US
dc.titleBoyuna uzatılmış yüzeylerde dikdörtgensel oyukların ısı atımına etkisi: Bir hesaplamalı akışkanlar dinamiği analizien_US
dc.title.alternativeImpacts of rectangular perforations in longitudinal extended surfaces on heat dissipation: A computational fluid dynamics analysisen_US
dc.typearticleen_US
dc.relation.journalAfyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisien_US
dc.departmentSeçinizen_US
dc.authorid0000-0003-0150-4705en_US
dc.identifier.volume20en_US
dc.identifier.startpage931en_US
dc.identifier.endpage940en_US
dc.identifier.issue5en_US