dc.contributor.author | Tunçkaya, Yasin | |
dc.date.accessioned | 2021-10-27T08:21:48Z | |
dc.date.available | 2021-10-27T08:21:48Z | |
dc.date.issued | 20.05.2020 | en_US |
dc.identifier.citation | Tunçkaya, Y. (2020). Bir Termik Enerji Santralinde Ana Buhar Sıcaklığı Parametresinin YSA ve ARIMA Yöntemleriyle Modellenmesi ve Kestirim Performanslarının Araştırılması . Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi , 20 (2) , 237-249 . DOI: 10.35414/akufemubid.628232 | en_US |
dc.identifier.uri | https://dergipark.org.tr/tr/download/article-file/1106973 | |
dc.identifier.uri | https://doi.org/10.35414/akufemubid.628232 | |
dc.identifier.uri | https://hdl.handle.net/11630/9573 | |
dc.description.abstract | Dünyada enerji üretim yöntemleri arasında hala büyük bir yüzdeye sahip olan termik santraller, kömür
kullanımının çevreye olumsuz etkisi nedeniyle yoğun eleştirilere maruz kalmakla birlikte, elektrik ve
buhar gibi kritik çıktıları nedeniyle vazgeçilmez bir öneme sahiptir. Bu çalışmada, Türkiye’ de kurulu
bulunan 600 MW nominal üretim kapasitesine sahip termik santral prosesine yönelik yeni bir analiz
yapılmıştır ve seçilen kritik işletme parametreleri vasıtası ile Yapay Sinir Ağları (YSA) metodu kullanılarak
güncel bir modelleme çalışması gerçekleştirilmiştir. Santralin daha önceki dönemlere ait proses
değerleri veri madenciliği yöntemleri ile harmanlanarak, tesis verimliliği ve üretim miktarını etkilemesi
nedeniyle kilit bir parametre olan ana buhar sıcaklığı değerinin tahminlendiği bir kestirim çalışması
literatüre sunulmuştur. YSA modeli çıktıları, istatistiksel veri analiz ve kestirim yöntemlerinden biri olan
Otoregresif Entegre Hareketli Ortalama (ARIMA) yöntemi ile karşılaştırılmıştır. Determinasyon katsayısı
ve ortalama kök karesel hata yaklaşımı hesaplamaları ile başarım ve hata analizinin yapıldığı çalışmada,
optimum YSA modeli için bu performans değerleri sırasıyla 0,994 ve 1,489 olarak bulunmuştur ve
sistemin yüksek başarı oranı ile tahminleme yaptığı gösterilmiştir. | en_US |
dc.description.abstract | Thermal power plants, which still have a large percentage of the energy production methods in the
world, are subject to intense criticism due to the negative impact of coal usage to the environment, but
indispensable because of their critical output such as electricity and steam. In the study, a novel analysis
is carried out to investigate the process of thermal power plant located in Turkey with 600 MW nominal
power output and the plant is modeled selecting the most critical operations parameters using Artificial
Neural Networks (ANN) approach. Past process data is obtained from the plant, blended using data
mining techniques, and presented literature to track and predict the main steam temperature, which is
a key parameter for plant’s efficiency and production rate, by various approaches and experiments. The
results off ANN model is compared with the Autoregressive Integrated Moving Average (ARIMA)
method, which is one of the statistical data analysis and estimation method. Performance and error
analysis is executed using determination coefficient and root mean square error approaches in the
study within optimum ANN model, these performance values are found as 0.994 and 1.489 respectively
and it is revealed that the system predicts with high success rate. | en_US |
dc.language.iso | tur | en_US |
dc.publisher | Afyon Kocatepe Üniversitesi | en_US |
dc.identifier.doi | 10.35414/akufemubid.628232 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Kestirim | en_US |
dc.subject | Otoregresif entegre hareketli ortalama | en_US |
dc.subject | Termik santral | en_US |
dc.subject | Yapay sinir ağları | en_US |
dc.subject | Artificial neural networks | en_US |
dc.subject | Autoregressive integrated moving average | en_US |
dc.subject | Prediction | en_US |
dc.subject | Thermal power plants | en_US |
dc.title | Bir termik enerji santralinde ana buhar sıcaklığı parametresinin ysa ve arıma yöntemleriyle modellenmesi ve kestirim performanslarının araştırılması | en_US |
dc.title.alternative | Modeling of main steam temperature parameter in a thermal power plant via ann and arıma methods and ınvestigation of prediction performances | en_US |
dc.type | article | en_US |
dc.relation.journal | Makale | en_US |
dc.department | Seçiniz | en_US |
dc.authorid | 0000-0002-6690-2694 | en_US |
dc.identifier.volume | 20 | en_US |
dc.identifier.startpage | 237 | en_US |
dc.identifier.endpage | 249 | en_US |
dc.identifier.issue | 2 | en_US |
dc.relation.publicationcategory | Makale - Ulusal - Editör Denetimli Dergi - Başka Kurum Yazarı | en_US |