Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSarpgün, İsmail Hakkı
dc.contributor.authorKoca, Timur
dc.contributor.authorAtak, Ece
dc.contributor.authorŞengün, Yasemin
dc.contributor.authorAksoy, Rahmi Atıl
dc.contributor.authorKızılkaya, Mehmet
dc.contributor.authorKorcum, Aylin Fidan
dc.date.accessioned2023-09-14T07:14:32Z
dc.date.available2023-09-14T07:14:32Z
dc.date.issued15.06.2022en_US
dc.identifier.citationSarpün, İ. H. , Koca, T. , Atak, E. , Şengün, Y. , Aksoy, R. A. , Kızılkaya, M. & Korcum, A. F. (2022). Variation of the Absorbed Dose by the Height of the Patient in CT Scanning . Afyon Kocatepe Üniversitesi Uluslararası Mühendislik Teknolojileri ve Uygulamalı Bilimler Dergisi , 5 (1) , 1-4 . DOI: 10.53448/akuumubd.985577en_US
dc.identifier.urihttps://dergipark.org.tr/tr/pub/akuumubd/issue/69929/985577
dc.identifier.urihttps://hdl.handle.net/11630/11001
dc.description.abstractKanser tedavilerinde çekilen Bilgisayarlı Tomografi (CT) görüntüleri, tedavi portalı tasarımı ve planlamasında önemlidir. Hastanın CT taramalarında aldığı doz, tedavi planlaması doz hesaplamasında dikkate alınmaz ve kritik doz eşiğine sahip kritik organların sınır dozlarının hesaplanmasında önem kazanır. Bu çalışmada bazı kritik organlar olan kalp, karaciğer ve böbreklerin hastanın boyuna göre aldığı dozun değişimi Monte Carlo tekniği kullanılarak NCICT kodu ile araştırıldı. Sonuç olarak, dozlar hastaların boyuna göre değiştirildi.en_US
dc.description.abstractComputed Tomography (CT) images taken in cancer treatments are important in treatment portal design and planning. The dose received by the patient in CT scans are not considered in the treatment planning dose calculation and becomes important in calculating the limit doses of the critical organs with critical dose threshold. In this study, the change of the dose received by some of the critical organs, namely the heart, liver, and kidneys, according to the height of the patient was investigated with the NCICT code using the Monte Carlo technique. As a result, doses were changed by the height of the patients.en_US
dc.language.isoengen_US
dc.publisherAfyon Kocatepe Üniversitesien_US
dc.identifier.doi10.53448/akuumubd.985577en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCTen_US
dc.subjectPhantomen_US
dc.subjectNCICTen_US
dc.subjectMonte Carloen_US
dc.titleCT taramalarında absorbe edilen dozun hastanın boyuna göre değişimien_US
dc.typearticleen_US
dc.relation.journalUluslararası Mühendislik Teknolojileri ve Uygulamalı Bilimler Dergisien_US
dc.departmentSeçinizen_US
dc.authorid0000-0002-9788-699Xen_US
dc.authorid0000-0002-7400-1837en_US
dc.authorid0000-0001-9215-5664en_US
dc.authorid0000-0001-8289-1713en_US
dc.authorid0000-0002-5399-5430en_US
dc.authorid0000-0003-0266-3919en_US
dc.authorid0000-0003-0318-6122en_US
dc.identifier.volume5en_US
dc.identifier.startpage1en_US
dc.identifier.endpage4en_US
dc.identifier.issue1en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster