dc.date.issued | 2016 | en_US |
dc.identifier.citation | Ruishu Feng, Justin Beck, Derek M. Hall, Aysel Buyuksagis, Serguei N. Lvov, Margaret Ziomek-Moroz, “Effects Of Co2 And H2s On Corrosion Of Martensitic Steels İn Nacl(Aq) At Low Temperature”, Nace Corrosion 2016, March 6-10, Vancouver Convention Center, Vancouver, Bc, Canada , Paper No:7659 | en_US |
dc.identifier.uri | http://nacecorrosion.org/ | |
dc.identifier.uri | https://hdl.handle.net/11630/7591 | |
dc.description.abstract | Corrosion studies were conducted for martensitic carbon steels in brine solutions at 4 °C and 10 MPa (1450 psi), which simulated the subsurface environments encountered in Arctic drilling. Three environments with a 5 % wt. NaCl brine were used: (1) 0.312 mole of CO2 per mole of H2O in brine, (2) 3.12 x 10-4 mole of H2S per mole of H2O in brine, and (3) a mixture of 3.12 x 10-4 mole H2S and 0.312 mole CO2 per mole of H2O in brine. Two martensitic carbon steels were selected for the investigations: a high strength low alloy (HSLA) carbon steel commonly used for drill pipe (G41000) and a newly designed ultra-high strength low alloy (UHSLA) steel (G41300). Electrochemical and mass loss measurements found corrosion rates on the order of 0.05 mm y-1 in the systems containing H2S and CO2+H2S, while the CO2 systems saw corrosion rates between 0.5 and 2 mm y-1. Surface analyses of the tested samples were performed using scanning electron microscopy and energy dispersive X-ray spectroscopy to identify corrosion products. The corrosion products were unstable and oxidized quickly after taking out of the system. All samples had a high oxygen content across the surface, though the samples exposed to H2S and CO2+H2S had relatively higher levels of sulfur present in an inner region of the film. Experimental corrosion rates were compared to model predictions, and a good agreement was found for the CO2 and H2S cases. However, the model predicted that corrosion rates in the mixed case would match those of the CO2-only system. The experimental results showed that CO2:H2S ratios as high as 1000 can result in predominantly sour corrosion at the low temperature, high pressure conditions tested. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Nace International | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | H2S Corrosion | en_US |
dc.subject | CO2 Corrosion | en_US |
dc.subject | Martensitic Carbon Steels | en_US |
dc.subject | Corrosion Rate | en_US |
dc.subject | Corrosion Scales | en_US |
dc.subject | Cold Climate Conditions | en_US |
dc.title | Effects of CO2 and H2S on corrosion of martensitic steels in NaCl(aq) at low temperature | en_US |
dc.type | conferenceObject | en_US |
dc.relation.journal | NACE CORROSION 2016 | en_US |
dc.department | Fen-Edebiyat Fakültesi | en_US |
dc.authorid | 0000-0001-8911-7157 | en_US |
dc.identifier.startpage | 7659 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Büyüksağiş, Aysel | |