The effect of voltage on the arc stud welding of microwave sintered Fe+Al powder mixture
Abstract
The joining of powder metallurgy products is of importance because of high demand in many
industrial applications. In this study, the effect of welding voltage on the joint quality has been
investigated using discharge arc stud welding, a low heat input welding method, without gas protection
to join steel stubs to microwave sintered compacts containing a powder mixture of 26 atomic % Al
and Fe (balance). It has been shown that welds with steel stubs are prone to side cracking in the weld
zone and they also suffer from the oxidation of metal powders adjacent to the weld zone. The forms of
oxides are continuous and laminar type in welds with steel stubs and the composition of weld zone
changes with increasing arc voltage.
Source
SciELOVolume
17Issue
3URI
https://doi.org/10.1590/S1516-14392014005000081http://www.scielo.br/pdf/mr/v17n3/aop_matres_229413.pdf
https://hdl.handle.net/11630/8018