Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.advisorBayram, İsmail
dc.contributor.authorGümüştaş, Ömer
dc.date.accessioned2020-10-07T08:38:54Z
dc.date.available2020-10-07T08:38:54Z
dc.date.issued20.04.2017en_US
dc.date.submitted2017-04-20
dc.identifier.urihttps://hdl.handle.net/11630/8410
dc.description.abstractBu araştırma, Türkiye’de ilk defa olmak üzere, mısır tarımının yoğun olarak yapıldığı yedi ayrı bölgeden toplanan 320 adet tane mısır numunesinde Asit Deterjan Fiber (ADF) düzeyinin belirlenmesinde NIR kalibrasyonunun oluşturulması amacıyla gerçekleştirilmiştir. Toplanan 320 adet mısır numunesi önce öğütülmüş ve sonrasında her birinden ayrı ayrı spektralar toplanmıştır. Mısır numunelerinin kemometrik (yaş kimyasal) metotla referans analizleri yapılarak kalibrasyon çalışmaları yürütülmüştür. Araştırmada, bulunan spektralara ön uygulama olarak birinci türev gap 2 (first derivate gap 2) standart normal varyasyon (SNV) ve çarpımsal dağılım düzeltmesi (multiplicative scatter correction; MSC) uygulanılmıştır. Araştırmada ayrıca regresyon analiz metodu olarak PLS kullanılmıştır. Oluşturulan kalibrasyon setinin R=0.5544; R2= 0.3074 Standart Sapma = 0.6256 şeklinde değerleri alınmış, validasyon setinden ise R=0.4489; R2= 0.2015 Standart Sapma = 0.5623 değerleri elde edilmiştir. Kalibrasyon aralığı 1.074 olmuşken, validasyon aralığı 1.577 olarak belirlenmiştir. Sonuç olarak; Türkiye'nin mısır tarımının yoğun yapıldığı 7 farklı bölgesinden toplanan tane mısırın ADF içeriği ile ilgili olarak kalibrasyon geliştirilmeye çalışılan bu araştırmada üzerinde çalışılan numune sayısı doğru ve güvenilir bir kalibrasyon için yeterli gelmemiştir. Bu yüzden daha kapsamlı ve daha fazla numuneyle yapılacak çalışmalara gereksinim bulunmaktadır.en_US
dc.description.abstractThis research was conducted for the purpose of establishing NIR calibrations at the determination of the level of Acid Detergent Fiber (ADF) on 320 corn samples collected from seven different regions where corn agriculture was intensively made for the first time in Turkey. 320 corn samples collected were first grind and then spectra were collected separately from each other. Calibration studies were carried out by reference analysis of the corn samples with chemometric (wet chemical) method. In the study, the first derivative gap 2 (SNV) and the multiplicative scatter correction (MSC) were applied as the spectral approach. PLS was also used as a regression analysis method in the study. Calibration set generated is R = 0.5544; R2 = 0.3074 Standard Deviation = 0.6256, R = 0.4489 from the validation set; R2 = 0.2015 Standard Deviation = 0.5623 values were obtained. While the calibration interval was 1,074, the validation interval was set at 1,577. As a result; The number of samples studied in this study was not sufficient for a reliable and accurate calibration in this survey where calibration is being developed with regard to the ADF content of grain corn collected from 7 different regions of Turkey where corn agriculture is intensively cultivated. This means that there is a need for more extensive and more sample work.en_US
dc.description.sponsorshipBu Tez Afyon Kocatepe Üniversitesi Bilimsel Araştırma Projeleri Komisyonu tarafından 14.SAĞ.BİL.15 proje numarası ile desteklenmiştir.en_US
dc.language.isoturen_US
dc.publisherAfyon Kocatepe Üniversitesi, Sağlık Bilimleri Enstitüsüen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAsit Deterjan Fiber (ADF)en_US
dc.subjectMısıren_US
dc.subjectNIRen_US
dc.subjectKalibrasyonen_US
dc.titleMısır tanesinde adf analizi için nır kalibrasyonu oluşturulmasıen_US
dc.title.alternativeNeutral calibration for adf analysis in corn grainen_US
dc.typemasterThesisen_US
dc.departmentSağlık Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster